BREATHER VALVE

Professional manufacturer and designer of BREATHER VALVE

HXF5 type fire resistance single exhalation valve
Hot
BREATHER VALVE Model:HXF5

HXF5 type fire resistance single exhalation valve

HXF5 type fire arrester single breath valve is our company's best product, which integrates flame arrester and single breath valve. It is a new type of safety equipment necessary for petrochemical storage tanks. It has good performance, light weight and convenient maintenance. This product is suitab...

Pressure Range
Temperature
Body Material
DN Size
Description

HXF5 type fire arrester single breath valve is our company's best product, which integrates flame arrester and single breath valve. It is a new type of safety equipment necessary for petrochemical storage tanks. It has good performance, light weight and convenient maintenance. This product is suitable for storage of Class A oil products with a flash point below 28°C and Class B oil products with a flash point below 60°C: such as gasoline, kerosene, diesel, crude oil, toluene, ethanol, aviation oil, food oil and other media storage Can be used, it works normally in a temperature environment of minus 29℃~60℃.

Operating pressure

Exhalation pressure

+980Pa

(+100mm H2O)

Maintenance and maintenance

In order to ensure the normal use of HXF5 type fire-stop single exhalation valve.

1. The corrugated fire barrier should be removed and cleaned regularly within 3-6 months to ensure that each hole on the fire barrier is unblocked to prevent clogging and ensure safe and normal use.

2. Regularly check whether the positive valve disc for ventilation is flexible, and whether the contact seal between the guide rod and the valve disc is damaged. If there is any damage, it should be replaced immediately.

3. During inspection, maintenance, and re-installation, it is necessary to ensure that the joint surfaces in the valve are tightly matched, and the valve disc rises and falls flexibly.

4. When the new valve is started, the anti-vibration material of the valve disc should be removed before installation, otherwise the exhalation valve will fail.

5. Because the weather is humid and windy and the temperature reaches zero degrees, the storage tank cannot be used for sending oil. In emergency production, the oil metering hole and other gas supply products must be opened first to maintain the safety function of the storage tank.

6. Before the fire-stop single-exhalation valve works normally, the oil metering hole must be opened first.

Operating pressure

Exhalation pressure

+980Pa

(+100mm H2O)

Maintenance and maintenance

In order to ensure the normal use of HXF5 type fire-stop single exhalation valve.

1. The corrugated fire barrier should be removed and cleaned regularly within 3-6 months to ensure that each hole on the fire barrier is unblocked to prevent clogging and ensure safe and normal use.

2. Regularly check whether the positive valve disc for ventilation is flexible, and whether the contact seal between the guide rod and the valve disc is damaged. If there is any damage, it should be replaced immediately.

3. During inspection, maintenance, and re-installation, it is necessary to ensure that the joint surfaces in the valve are tightly matched, and the valve disc rises and falls flexibly.

4. When the new valve is started, the anti-vibration material of the valve disc should be removed before installation, otherwise the exhalation valve will fail.

5. Because the weather is humid and windy and the temperature reaches zero degrees, the storage tank cannot be used for sending oil. In emergency production, the oil metering hole and other gas supply products must be opened first to maintain the safety function of the storage tank.